Parameters
Command and Drive Data Sets – Overview
1-300
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
p1113[0...2] BI: Reverse / Reverse
p1124[0...2] BI: Enable JOG ramp times / Enable JOG ramp
p1140[0...2] BI: RFG enable / RFG enable
p1141[0...2] BI: RFG start / RFG start
p1142[0...2] BI: RFG enable setpoint / RFG enable setp
p1230[0...2] BI: Enable DC braking / Enable DC brk.
p1330[0...2] CI: Voltage setpoint / Voltage setp.
p1477[0...2] BI: Set integrator of n-ctrl. / Set integrator
p1478[0...2] CI: Set integrator value n-ctrl. / Set int. value
p1492[0...2] BI: Enable droop / Enable droop
p1500[0...2] Selection of torque setpoint / Torque setp. sel.
p1501[0...2] BI: Change to torque control / BI:-> torque ctrl.
p1503[0...2] CI: Torque setpoint / Torque setp.
p1511[0...2] CI: Additional torque setpoint / Add. trq. setp
p1522[0...2] CI: Upper torque limit / Upper trq. lim
p1523[0...2] CI: Lower torque limit / Lower trq. lim
p2103[0...2] BI: 1. Faults acknowledgement / 1. Faults ackn
p2104[0...2] BI: 2. Faults acknowledgement / 2. Faults ackn
p2106[0...2] BI: External fault / External fault
p2200[0...2] BI: Enable PID controller / Enab. PID ctrl
p2221[0...2] BI: Fixed PID setp. select Bit 1 / BI:PID setp->Bit 1
p2222[0...2] BI: Fixed PID setp. select Bit 2 / BI:PID setp->Bit 2
p2223[0...2] BI: Fixed PID setp. select Bit 3 / BI:PID setp->Bit 3
p2235[0...2] BI: Enable PID-MOP (UP-cmd) / PID-MOP (UP)
p2236[0...2] BI: Enable PID-MOP (DOWN-cmd) / PID-MOP (DWN)
p2241[0...2] BI: PID-MOP select setpoint auto/manu / Setp. auto/manu
p2242[0...2] CI: PID-MOP auto setpoint / PMOP auto setpoint
p2243[0...2] BI: PID-MOP accept rampgenerator setpoint / PMOP acc RFG setpo
p2244[0...2] CI: PID-MOP rampgenerator setpoint / PMOP RFG setpoint
p2253[0...2] CI: PID setpoint / PID setpoint
p2254[0...2] CI: PID trim source / CI:PID trim source
p2264[0...2] CI: PID feedback / PID feedback
p2480[0...2] BI: Enable positioning ramp down / Enable positioning
p2803[0...2] Enable FastFFBs / Enable FastFFBs
Parameters P0800, P0801, P1522, P1523, P2200 will be altered in the state "Ready" only,
all other parameters will be altered during data set switchover (CDS) in the state "Run".

Table of Contents

Other manuals for Siemens CU240S DP-F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240S DP-F and is the answer not in the manual?

Siemens CU240S DP-F Specifications

General IconGeneral
BrandSiemens
ModelCU240S DP-F
CategoryControl Unit
LanguageEnglish

Related product manuals