6.6.4 Adapt parameter list
You can make all of the essential settings after commissioning using the setting web pages.
In certain cases, it may be necessary to make extra settings or evaluations of status and
measured value outputs.
The available parameter list in which you can view or change all the available device
parameters, is used for this purpose.
You will find a detailed description of all S210 parameters in the following Section:
Parameters (Page 225).
Parameter types used in the parameter list
There are two main groups for the parameters:
● Adjustable parameters
Adjustable parameters are identified by a frame in which you can either enter values or
select values via drop-down menus. Invalid values have a red background and are rejected.
&RQWUROOHUWXQLQJQRLVHDPSOLWXGH
/RZHURUXSSHU
YDOXHOLPLW
H[FHHGHG
,QDFWLYH
① Adjustable parameters with this icon have several indices or bit arrays
② Name of the parameter
③ Input field for the parameter value
④ Select the parameter value via the drop-down menu
⑤ Invalid value
⑥ Unit of the parameter
Figure 6-14 Example of the representation of an adjustable parameter
● Display parameters
Display parameters are for information purposes only and cannot be changed.
6WDWRUZLQGLQJWHPSHUDWXUHr&
① Display parameters with this icon have several indices or bit arrays
Figure 6-15 Example of the representation of a display parameter
Calling the parameter list
Select "Parameters" and "Parameter list" in the navigation. The "Parameters - Parameter List"
view is displayed.
Commissioning and diagnostics in the Web server