F13009 Licensing Technology Extension not licensed
Message value: %1
Drive object: All objects
Reaction: OFF1
Acknowledge: IMMEDIATELY
Cause: At least one Technology Extension that requires a license does not have a license.
Note:
Refer to r4955 and p4955 for information about the installed Technology Extensions.
Remedy: - enter and activate the license key for Technology Extensions that require a license (p9920, p9921).
- if necessary, deactivate Technology Extensions that are not licensed (p4956).
F13010 Licensing function module not licensed
Message value: %1
Drive object: All objects
Reaction: OFF1
Acknowledge: IMMEDIATELY
Cause: At least one function module requiring a license is not licensed.
Fault value (r0949, interpret hexadecimal):
Bit x = 1: The corresponding function module does not have a license.
Note:
Assigning bit number to function module, see p0108 or r0108.
Remedy: - enter and activate the license key for function modules that require a license license (p9920, p9921).
- if necessary, deactivate unlicensed function modules (p0108, r0108).
A13021 License for 600 Hz is not sufficient
Message value: -
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: You have parameterized speeds that result in output frequencies >550Hz. For SINAMICS drives, output frequencies
>550Hz are only possible after enabling the corresponding high output frequency license. Without license, the SINAMICS
output frequencies are limited to 550 Hz (independent of any other parameterization).
Remedy: - enter and activate the license key for 600Hz.
- if required deactivate use of 600 Hz
F13100 Know-how protection: Copy protection error
Message value: %1
Drive object: All objects
Reaction: OFF1
Acknowledge: IMMEDIATELY
Cause: The know-how protection with copy protection for the memory card is active.
An error has occurred when checking the memory card.
Fault value (r0949, interpret decimal):
0: A memory card is not inserted.
2: An invalid memory card is inserted.
3: The memory card is being used in another Control Unit.
12: An invalid memory card is inserted (OEM input incorrect, p7769).
13: The memory card is being used in another Control Unit (OEM input incorrect, p7759).
Faults and alarms
13.2 List of faults and alarms
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA 491