Setting the temperature monitoring of the external braking resistor
If you have connected the external braking resistor with motor temperature monitoring, you
must activate the temperature monitoring via the web server of the converter.
Configuring digital inputs (Page 127).
Activate the digital input DI 4 "Temperature monitoring of the external braking resistor".
The converter switches the motor off as soon as the external braking resistor is too hot or when
no external braking resistor is connected (wire break).
Configuring
3.4 Configuring the external braking resistor
SINAMICS S210 servo drive system
54 Operating Instructions, 12/2017, A5E41702836B AA