Data type
The following data types are available for the parameters:
Integer8 I8 8-bit integer
Integer16 I16 16-bit integer
Integer32 I32 32-bit integer
Unsigned8 U8 8-bit without sign
Unsigned16 U16 16-bit without sign
Unsigned32 U32 32-bit without sign
FloatingPoint32 Float 32-bit floating-point number
P group
Specifies the functional group to which this parameter belongs.
Scaling
Specification of the reference variable with which a signal value is automatically converted
with a BICO interconnection.
The following reference variables are available:
p2000 … p2003: Reference speed, reference voltage, etc.
PERCENT: 1.0 = 100%
4000H: 4000 hex = 100% (word) or 4000 0000 hex = 100% (double word)
Parameter values
Min
Minimum value of the parameter [unit]
Max
Maximum value of the parameter [unit]
Def
Value when delivered [unit]