EasyManua.ls Logo

Siemens SINAMICS S210 - Page 179

Siemens SINAMICS S210
768 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Property Version
Climatic environmental con‐
ditions
1)
Temperature range: - 15 °C
1)
… + 40 °C
Relative humidity: 5 … 95%, condensation not permitted
Absolute air humidity: 1 ...29 g/m³
Rate of temperature change
2)
: 0.5°/min
Atmospheric pressure: 89
1), 3)
... 106 kPa
4)
Solar radiation: 700 W/m²
2)
Movement of the air: 1.0 m/s
Water (other than rain): See protection class
Mechanical environmental
conditions
Vibration levels permissible according to Class 3M8 to EN 60721-3-3: Max. 50 m/s²
Shock permissible according to Class 3M8 to EN 60721-3-3
Protection against chemical
substances
Protected according to 3C2 to EN 60721‑3‑3
Biological environmental
conditions
Suitable according to 3B2 to EN 60721‑3‑3
Pollution Suitable for environments with degree of pollution 2 according to EN 61800-5-1
Cooling air Clean and dry air
The motors are not suitable for operation
In a vacuum
5)
In salt-laden or aggressive atmospheres
Outdoors
1)
Increased ruggedness with regard to low temperature and low atmospheric pressure better than 3K3 according to EN
60721-3-3
2)
Averaged over a period of 5 min
3)
The limit value of 89 kPa covers applications at altitudes up to 1000 m.
4)
Conditions in mines are not considered.
5)
Operation in a vacuum is not permissible because of the low dielectric strength and poor heat dissipation.
Technical specifications
8.1 Technical data and properties of the motor
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA 177