03 Operation enable missing Yes No -
04 Armature short-circuit / DC braking enable missing Yes No 7014,
7016
05 STOP2 enable missing Yes No -
08 Safety enable missing Yes No -
09 Infeed enable missing Yes No -
10 Ramp-function generator enable missing Yes No -
11 Ramp-function generator start missing Yes No -
12 Setpoint enable missing Yes No -
16 OFF1 enable internal missing Yes No -
17 OFF2 enable internal missing Yes No -
18 OFF3 enable internal missing Yes No -
19 Pulse enable internal missing Yes No -
20 Armature short-circuit/DC braking internal enable missing Yes No 7014,
7016
21 STOP2 enable internal missing Yes No -
25 Function bypass active Yes No -
26 Drive inactive or not operational Yes No -
27 De-magnetizing not completed Yes No -
28 Brake open missing Yes No -
29 Cooling unit ready signal missing Yes No -
30 Speed controller inhibited Yes No -
31 Jog setpoint active Yes No -
Dependency: See also: r0002
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA 231