EasyManua.ls Logo

Siemens SINAMICS S210 - Page 385

Siemens SINAMICS S210
768 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remedy: For message value = 0:
- no error was identified in this monitoring channel. Observe the error message of the other monitoring channel (C30711)
For message value = 3:
Commissioning phase:
- check encoder parameters, and if required, correct (p9516, p9517, p9518, p9520, p9521, p9522, p9526).
In operation:
- check the mechanical design and the encoder signals.
For message value = 232:
- increase the hysteresis tolerance (p9547). Possibly set the filtering higher (p9545).
For message value = 1 ... 999:
- if the message value is listed under cause: Check the cross-checked parameters to which the message value refers.
- copy the safety parameters.
- carry out a POWER ON (switch-off/switch-on) for all components.
- upgrade the drive software.
- correction of the encoder evaluation. The actual values differ as a result of mechanical faults (V belts, travel to a
mechanical endstop, wear and window setting that is too narrow, encoder fault, ...).
For message value = 1001:
- carry out a POWER ON (switch-off/switch-on) for all components.
- upgrade the drive software.
For message value = 1005:
- check the conditions for deselecting STO.
For message value = 1007:
- check the PLC for the correct operating state (run state, basic program).
For message value = 1011:
- for diagnostics, refer to parameter (r9571).
For message value = 1012:
- upgrade the Sensor Module firmware to a more recent version.
- check encoder parameters to ensure that they are the same (p9515, p9519, p9523, p9524, p9525, p9529).
- to correctly copy the encoder parameters from p04xx, p9700 must be set = 46 and p9701 = 172.
- for DQI encoders the following applies: If required, upgrade the firmware version of the Control Unit to a more recent
version, which is released for DQI encoders.
- check the electrical cabinet design and cable routing for EMC compliance
- carry out a POWER ON (power off/on) for all components or a warm restart (p0009 = 30, p0976 = 2, 3).
- replace the hardware.
For message value = 1020, 1021:
- check the communication link.
- carry out a POWER ON (power off/on) for all components or a warm restart (p0009 = 30, p0976 = 2, 3).
- replace the hardware.
For message value = 1033, 1034:
- if required, upgrade the firmware version of the Control Unit to a more recent version, which is released for DQI encoders.
For message value = 1035, if one of the safety encoders was replaced:
- acknowledge hardware replacement.
- save all parameters
- acknowledge fault (e.g. BI: p2103).
For message value = 1039:
- check the conversion factors such as spindle pitch or gearbox ratios.
For message value = 5000, 5014, 5023, 5024, 5030, 5031, 5032, 5042, 5043, 5052, 5053, 5068, 5072, 5073, 5082 ...
5087, 5090, 5091, 5122 ... 5125, 5132 ... 5135, 5140:
- carry out a POWER ON (switch-off/switch-on) for all components.
- upgrade firmware to later version.
- contact Technical Support.
- replace drive.
For message value = 5012:
Faults and alarms
13.2 List of faults and alarms
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA 383

Table of Contents

Related product manuals