EasyManua.ls Logo

Siemens SITRANS F - 4.2 THE TABLE SETUPS MENU

Siemens SITRANS F
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setup
3.4 Inputs and outputs
FST030
168 Function Manual, 04/2017, A5E35693328-AA
Setting
Volume flow; Mass flow; Standard volume flow (only hydrocarbon and gas applications);
Flow velocity; Sound velocity; LiquIdent (only hydrocarbon applications); Density; Kinemat-
ic viscosity; Pressure; Medium temperature; Standard density (only hydrocarbon and gas
applications); Standard kinematic viscosity (only hydrocarbon applications); API gravity
(only hydrocarbon applications); Standard API gravity (only hydrocarbon applications);
Specific gravity (only hydrocarbon applications); Standard specific gravity (only hydrocar-
bon and gas applications); Auxiliary temperature; Sen
sor temperature; Standardizing factor
(only hydrocarbon and gas applications)
Default
Volume flow
Related
Path
Setup → Inputs and outputs → Channel 4 - input/output → Current output → Process value
3.4.7.5.2 Direction
Description
Flow direction filter applicable for process values mass flow/volume flow/flow
velocity/standard volume flow rate (only hydrocarbon and gas applications).
Setting
Positive; Negative; Bidirectional; Bidirectional (symmetric)
Default
Positive
Related
Path
Setup → Inputs and outputs → Channel 4 - input/output → Current output → Direction
3.4.7.5.3 Loop current scale
Description
Sets current output scaling according to desired measurement range. Format: <Nominal
range> (<lower fault current>) <lower saturation limit> to <upper saturation limit> (<upper
fault current>) [<Description>]
Setting 4 to 20 mA (3.50) 3.8 to 20.5 (22.6) NAMUR
4 to 20 mA (3.75) 4.0 to 20.8 (22.6) US
4 to 20 mA (0.00) 4.0 to 20.5 (22.0)
4 to 20 mA (2.00) 4.0 to 24.0 (25.0)
0 to 20 mA (0.00) 0.0 to 20.5 (22.0)
0 to 20 mA (0.00) 0.0 to 24.0 (25.0)
Default
4 to 20 mA (3.50) 3.8 to 20.5 (22.6) NAMUR
Related
Path
Setup → Inputs and outputs → Channel 4 - input/output → Current output → Loop current
scale

Table of Contents