6.8 Reflector
In Ethernet Reflector mode the Network Master loops incoming traffic on a port
swapping MAC and/or IP addresses.
HDX (Half Duplex) is not possible in 'Reflector' mode.
6.8.1 Ports Setup and Status
The first step in running an application is to set up the port interfaces. This is
done on the Ports Setup screen, which also provides port status
information.
The setup options and status information related to the Ethernet interface are
described in a separate section:
Ethernet Setup and Status
In Ethernet Setup for Reflector mode, two buttons appear in Navigation area.
Swap
Settings
Only "Incoming Frames" tab and "Receiver Setup" tab appear.
Incoming Frames tab is different from that in other applications.
In Src MAC and Src IP, set the source MAC address and the source IP
address of ARP request and Ping request.
For applications also including an OTN interface, you can find a description
of the setup options and status information for OTN in the following section:
OTN Setup and Status
Ethernet Applications Reflector