14-23
Chapter 14. Appendix
Description User's Manual Reference User's Manual Change
Support for MOTOR block
3 - 3 Crimp Terminals
Recommended Ferrules (p.3-4)
Added the content at left
4 - 13 Motor Drive Output (Position
Proportional Control) (p.4-75)
Added the content at left
6 - 1 Operation Display Data
1-loop monitor screen (p.6-2)
Added a description for the
display of MFB and motor drive
output to Variable display”
6 - 2 Parameter Setting Display Data
PP (position proportional) bank (p.6-33)
Added the content at left
11 - 2 Alarm
Block alarm (p.11-3)
Added MOTOR (slot B2) to “Block
alarm
Chapter 13. Specifications
MOTOR block (p.13-6)
Added the content at left
14 - 2 Standard Bit Codes and Standard
Numerical Codes
Standard bit codes (p.14-6)
Added MFB input error, MFB
is under adjustment, MFB
estimation in progress, MFB
adjustment error, Motor drive
output OPEN, and Motor drive
output CLOSE
Added PV Hold to AI (Analog Input)
4 - 2 AI (Analog Input)
Function block diagram
Added PV Hold
4 - 2 AI (Analog Input)
PV Hold (p.4-10)
Added the content at left
Added Hold PV, Control operation
direct/reverse selection, and Timer
stop/start selection to the operations
of DI (Digital Input)
4 - 8 DI (Digital Input) (p.4-49)
DI assignment (p.4-50)
Setting items table (p.4-50)
Operation types table (p.4-53)
Added PV hold, Control
operation direct/reverse
selection, and Timer stop/start
selection to “Operation types”
6 - 2 Parameter Setting Display Data
DI bank (p.6-22)
Same as above
Added 13 operation types to the
events
4 - 9 Events
Operation (p.4-56),
Operation type and Loop definition (p.4-61)
Added MFB high and low limits,
standard numerical code high
limit, standard numerical code
low limit, standard numerical
code high and low limits, PV
change rate high limit, PV
change rate low limit, standard
numerical code change rate high
limit, standard numerical code
change rate low limit, During AT
(status), SP ramp (status), Control
direct action (status), MFB
estimation in progress (status),
and Timer to “Operation types”
Added standard numbers to
“Loop definition
6 - 2 Parameter Setting Display Data
EVENT CONFIG bank (p.6-17)
Same as above