Programmable Outputs 205
17 Sensor Watch Alarm
This output will operate when the sensor watch count has been reached. Refer to Zone
Options 1 on page 175 for more information on programming zones for sensor watch.
Refer to "LOCATION 420 - 421" on page 218 for setting how many days before a zone can
register as a faulty sensor watch zone.
18 Codepad Medical Alarm
This output will operate when pressing the
7 and 9 buttons simultaneously on the
remote codepad has activated a codepad medical alarm. This output will reset once a valid
user code has been entered at the remote codepad.
19 Codepad Fire Alarm
This output will operate when a codepad medical alarm has been activated by pressing the
4 and 6 buttons on the remote codepad simultaneously. This output will reset once a
valid user code has been entered at the remote codepad.
1 Codepad Panic Alarm
This output will operate when a codepad panic alarm (audible or silent) has been activated
by pressing the
1 and 3 buttons or the and buttons on the remote codepad
simultaneously. This output will reset once a valid user code has been entered at the
remote codepad.
1 Codepad Duress Alarm
This output will operate when a duress alarm has been activated by adding a
9to the end
of the user code being used to disarm the system. This output will reset the next time the
system has been armed.
1 Codepad Tamper – Access Denied
This output will operate when the wrong code has been entered more times than allowed.
Refer to "LOCATION 368 - 370" on page 195 for setting the number of incorrect attempts
that may be allowed. This output will reset once a valid user code has been entered.
1 Speaker Beeps
This output will function during all remote radio/keyswitch operations allowing you to fit a
12V DC buzzer or light to provide status indication for the end user. Refer to the table
below for the identification beeps and their meanings.
No Of Beeps System Status
1
System Disarmed
2
System Armed In AWAY Mode
3
System Armed In STAY Mode 1
Table 116: Horn Speaker Beeps
1 Horn Speaker (Output 1 Only)
This output will operate only on Output 1 and should be programmed whenever an 8-ohm
horn speaker is required. A maximum of two horn speakers may be used. Refer to
“LOCATION 423” on page 219 for setting the siren run time and “LOCATION 424” on
page 219 for setting the siren sound rate.
If you require monitoring of the horn speaker, refer to Option 2 in “LOCATION 436” on
page 227.