Programmable Outputs 209
47 Zone Not Sealed After Exit Time
This output will operate at the end of exit time if a burglary zone is unsealed. The output
will reset when all zones are sealed or the system has been disarmed. Chime zones will not
operate this output event type.
49 AC Mains 60 Hz Or 50 Hz
This output will activate when the AC mains supply frequency is at 60 Hz. The output will
reset once the AC mains supply has returned to 50 Hz.
The following output event types are only applicable to the Solution Ultima 880 control panel
when partitioned.
4 Area 1 Has Zone Unsealed 4 Area 2 Has Zone Unsealed
These two outputs will operate when a zone in their corresponding area has registered as
unsealed when the area is either armed in AWAY Mode or STAY Mode, or the area is
disarmed.
Example
Zone 1 is allocated to Area 1. If Zone 1 becomes unsealed, Output Event Type 4,10 will
operate. The output will reset once the zone has resealed.
52 Area 1 In Alarm 53 Area 2 In Alarm
These two outputs will operate when a zone in their corresponding area has registered an
alarm. These outputs will reset once a valid user code has been entered.
Example
Zone 1 has been allocated to Area 1. If Zone 1 has registered an alarm, Output Event Type
5,2 will operate. The output will reset once a valid user code allocated to operate Area 1
has been entered.
56 Area 1 Is Armed 57 Area 2 Is Armed
These two outputs will operate when their corresponding area has been armed in AWAY
Mode or STAY Mode 1. The output will reset once the corresponding area is disarmed.
Example
If area 1 has been armed in AWAY Mode or STAY Mode 1, Output Event Type 5,6 will
operate. The output will reset once Area 1 is disarmed.
5 Area 1 Is Disarmed 5 Area 2 Is Disarmed
These two outputs will operate when their corresponding area has been disarmed. The
output will reset once the corresponding area is armed.
Example
If Area 1 has been disarmed, Output Event Type 5,10 will operate. The output will reset
once Area 1 is disarmed.
5 Any Areas Armed
This output will operate when either Area 1 or Area 2 has become armed in AWAY Mode
or STAY Mode 1. The output will reset when both areas are disarmed.
5 Any Areas Disarmed
This output will operate when either Area 1 or Area 2 has become disarmed. The output
will reset when both areas are armed in either AWAY Mode or STAY Mode 1.