Description of device parameters Proline Promag 300 Modbus RS485
64 Endress+Hauser
Volume offset
Navigation Expert → Sensor → System units → User-spec. units → Volume offset (0569)
Description Use this function to enter the offset for adapting the user-specific volume unit and volume
flow unit (without time).
User entry Signed floating-point number
Factory setting 0
Additional information Description
Value in user-specific unit = (factor × value in base unit) + offset
Volume factor
Navigation Expert → Sensor → System units → User-spec. units → Volume factor (0568)
Description Use this function to enter a quantity factor (without time) for the user-specific volume and
volume flow unit.
User entry Signed floating-point number
Factory setting 1.0
Mass text
Navigation Expert → Sensor → System units → User-spec. units → Mass text (0560)
Description Use this function to enter a text for the user-specific unit of mass and mass flow. The
corresponding time units (s, min, h, d) for mass flow are generated automatically.
User entry Max. 10 characters such as letters, numbers or special characters (@, %, /)
Factory setting User mass