Proline Promag 300 Modbus RS485 Modbus RS485 Register Information
Endress+Hauser 257
6.3.8 "Diagnostics" submenu
Navigation: Expert → Diagnostics
Parameter Register Data type Access Selection / User entry / User interface →
Actual diagnos. (0691) 2732 Integer Read Symbol for diagnostic behavior,
diagnostic code and short message.
172
Prev.diagnostics (0690) 2734 Integer Read Symbol for diagnostic behavior,
diagnostic code and short message.
173
Time fr. restart (0653) 2624 Integer Read Days (d), hours (h), minutes (m) and
seconds (s)
174
Operating time (0652) 2631 Integer Read Days (d), hours (h), minutes (m) and
seconds (s)
174
"Diagnostic list" submenu
Navigation: Expert → Diagnostics → Diagnostic list
Parameter Register Data type Access Selection / User entry / User interface →
Diagnostics 1 (0692) 2736 Integer Read Symbol for diagnostic behavior,
diagnostic code and short message.
175
Diagnostics 2 (0693) 2738 Integer Read Symbol for diagnostic behavior,
diagnostic code and short message.
175
Diagnostics 3 (0694) 2740 Integer Read Symbol for diagnostic behavior,
diagnostic code and short message.
176
Diagnostics 4 (0695) 2742 Integer Read Symbol for diagnostic behavior,
diagnostic code and short message.
177
Diagnostics 5 (0696) 2744 Integer Read Symbol for diagnostic behavior,
diagnostic code and short message.
178
"Event logbook" submenu
Navigation: Expert → Diagnostics → Event logbook
Parameter Register Data type Access Selection / User entry / User interface →
Filter options (0705) 4596 Integer Read / Write 0 = Failure (F)
4 = Mainten. req.(M)
8 = Funct. check (C)
12 = Out of spec. (S)
16 = Information (I)
255 = All
179
"Device info" submenu
Navigation: Expert → Diagnostics → Device info
Parameter Register Data type Access Selection / User entry / User interface →
Device tag (0011) 2026 to 2041 String Read Max. 32 characters, such as letters,
numbers or special characters (e.g. @,
%, /).
182
Serial number (0009) 7003 to 7007.5 String Read A maximum of 11-digit character string
comprising letters and numbers.
182
Firmware version (0010) 7277 to 7280 String Read Character string in the format xx.yy.zz 182
Device name (0020) 7238 to 7245 String Read Promag300/500 183