Proline Promag 300 Modbus RS485 Description of device parameters
Endress+Hauser 79
"Empty pipe det." submenu
Navigation Expert → Sensor → Process param. → Empty pipe det.
‣
Empty pipe det.
Empty pipe det. (1860)
→ 79
Switch point EPD (6562)
→ 79
Response time (1859)
→ 80
New adjustment (6560)
→ 80
Progress (6571)
→ 80
Empty pipe value (6527)
→ 81
Full pipe value (6548)
→ 81
Meas. value EPD (6559)
→ 81
Empty pipe det.
Navigation Expert → Sensor → Process param. → Empty pipe det. → Empty pipe det. (1860)
Description Use this function to switch empty pipe detection on and off.
Selection • Off
• On
Factory setting Off
Switch point EPD
Navigation Expert → Sensor → Process param. → Empty pipe det. → Switch point EPD (6562)
Prerequisite The On option is selected in the Empty pipe det. parameter (→ 79).
Description Use this function to enter the percentage threshold value of the resistance in relation to
the adjustment values.
User entry 0 to 100 %
Factory setting 10 %