Configuring the ECN330-switch
951553-KDU 137 365 Uen D 2006-06-16
the connection is terminated for the session. (Range: 0 - 300 seconds;
Default: 300 seconds)
Exec Timeout – Sets the interval that the system waits until user input
is detected. If user input is not detected within the timeout interval, the
current session is terminated. (Range: 0 - 65535 seconds; Default:
600 seconds)
Password Threshold – Sets the password intrusion threshold, which
limits the number of failed logon attempts. When the logon attempt
threshold is reached, the system interface becomes silent for a specified
amount of time (set by the Silent Time parameter) before allowing the
next logon attempt. (Range: 0-120; Default: 3 attempts)
These parameters can only be configured in the CLI.
Password – Specifies a password for the line connection. When a
connection is started on a line with password protection, the system
prompts for the password. If the correct password is entered, the system
shows a prompt. (Default: No password)
Login – Enables password checking at login. Select authentication by
a entering single global password as configured for the Password
parameter, or by entering a password set up for a specific user-name
account. (Default: Local)
Web – Click System, Line, Telnet. Specify the connection parameters for Telnet
access, then click Apply.
Figure 25 Configuring the Telnet Interface