EasyManua.ls Logo

Ericsson ECN330 - 3 Maintenance; Replacing a Fuse

Ericsson ECN330
1226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
171553-KDU 137 365 Uen D 2006-06-16
3 Maintenance
3.1 Replacing a Fuse
Each ECN330 DC power supply is protected by a disposable fuse, which is
located on the rear panel (please refer to Figure 1 on page 5). If needed, replace
it with a new 20 A, 250 V fuse.
Warning!
First power off the ECN330 before replacing a DC power supply fuse.
To replace a fuse, follow these steps:
1. Remove the -48 VDC power source from the ECN330.
2. Unscrew the fuse holder counter-clockwise from its socket. Pull out the
blown fuse and discard it.
3. Insert a new 20 A, 250 V fuse into the fuse holder and then screw the holder
clockwise back into the fuse socket.
4. Reconnect the -48 VDC power source to the ECN330.

Table of Contents