Command Line Interface
9451553-KDU 137 365 Uen D 2006-06-16
Related Commands
ip igmp snooping query-max-response-time (section 7.21.10 on
page 946)
7.21.9 ip igmp snooping query-interval
This command configures the query interval. Use the no form to restore the
default.
Syntax
ip igmp snooping query-interval <seconds>
no ip igmp snooping query-interval
seconds - The frequency at which the ECN330-switch sends IGMP
host-query messages. (Range: 60-125)
Default Setting
125 seconds
Command Mode
Global Configuration
Example
The following shows how to configure the query interval to 100 seconds:
Console(config)#ip igmp snooping query-interval 100
Console(config)#