Command Line Interface
600 1553-KDU 137 365 Uen D 2006-06-16
Example
Time Commands
The system clock can be dynamically set by polling a set of specified time
servers (NTP or SNTP). Maintaining an accurate time on the ECN330-switch
enables the system log to record meaningful dates and times for event entries.
If the clock is not set, the ECN330-switch will only record the time from the
factory default set at the last bootup.
Table 48 Time Commands
Console#show logging sendmail
SMTP servers
-----------------------------------------------
192.168.1.19
SMTP minimum severity level: 7
SMTP destination email addresses
-----------------------------------------------
ted@this-company.com
SMTP source email address: bill@this-company.com
SMTP status: Enable
Console#
Command Function Mode Page
sntp client Accepts time from specified time servers GC 601
sntp server Specifies one or more time servers GC 602
sntp poll Sets the interval at which the client polls for time GC 603
show sntp Shows current SNTP configuration settings NE,
PE
604
clock timezone Sets the time zone for the ECN330’s internal clock GC 605
calendar set Sets the system date and time GC 606
show calendar Displays the current date and time setting GC 607