Troubleshooting
11711553-KDU 137 365 Uen D 2006-06-16
9 Troubleshooting
9.1 Diagnosing ECN330 Indicators
Table 157 Troubleshooting Chart
Symptom Cause Action
PWR LED is
off
DC power is
disconnected
Check if the DC power supply is connected to the
ECN330.
Check connections between the ECN330, the
power cables, and the DC power circuit.
Check the ECN330’s fuse condition. Replace the
fuse, if necessary.
PWR LED is
on red
The units internal
power supply is not
operating normally
Reboot the ECN330-switch to see if the condition
clears.
If the condition persists, replace the unit.
DIAG LED is
on red
The ECN330-
switch has detected
a fault
Power cycle the ECN330 to see if the condition is
cleared.
If the condition persists, replace the unit.
FAN LED is
on red
One or both cooling
fans have a fault, or
the ECN330 is
overheating
Check that there is enough free space around the
ECN330 to allow for adequate ventilation
Replace the fan tray if required.
CTRL LED is
off
ENC not present Contact Ericsson.
CTRL LED is
on red
Error in the ENC Log in to the CLI, check if the ECN330 is in Fallback
state. Check the log file for errors. Check the
interfaces configuration.
If the ECN330 is not in Fallback state, contact
Ericsson.