EasyManua.ls Logo

Ericsson ECN330 - Show Logging

Ericsson ECN330
1226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Line Interface
5911553-KDU 137 365 Uen D 2006-06-16
7.5.38 show logging
This command displays the configuration settings for logging messages to local
switch memory, to an SMTP event handler, or to a remote syslog server.
Syntax
show logging {flash | ram | sendmail | trap}
flash - Displays settings for storing event messages in flash
memory (that is, permanent memory).
ram - Displays settings for storing event messages in temporary
RAM (that is, memory flushed on power reset).
sendmail - Displays settings for the SMTP event handler
(page 599).
trap - Displays settings for the trap function.
Default Setting
None
Command Mode
Privileged Exec
Example
The following example shows that system logging is enabled, the message level
for flash memory is errors (that is, default level 3 - 0), and the message level
for RAM is debugging (that is, default level 7 - 0).
Console#show logging flash
Console#show logging flash
Syslog logging: Enabled
History logging in FLASH: level errors
Console#show logging ram
Syslog logging: Enabled
History logging in RAM: level debugging
Console#