Command Line Interface
7851553-KDU 137 365 Uen D 2006-06-16
7.13.6 show power mainpower
Use this command to display the current power status for the ECN330.
Command Mode
Privileged Exec
Example
Table 83 show power mainpower - Display Description
Console#show power mainpower
Unit 1 Mainpower Status
Maximum Available Power : 555 watts
System Operation Status : on
Mainpower Consumption : 15 watts
Thermal Temperature : 41 (in Celsius)
Software Version : Version 0x1B6F, Build 0x07
Console#
Field Description
Maximum
Available
Power
The available power budget for the ECN330
(configurable, see section 7.13.1 on page 779).
System
Operation
Status
The current operating power status for the ECN330
(displays on or off).
Mainpower
Consumption
The current power consumption on the ECN330 in watts.
Thermal
Temperature
The current internal temperature of the ECN330. Note
that the ECN330 automatically shuts down if the
measured temperature exceeds 80 degrees Celsius.