EasyManua.ls Logo

Ericsson ECN330 - Timeout Login Response

Ericsson ECN330
1226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Line Interface
574 1553-KDU 137 365 Uen D 2006-06-16
Example
Related Commands
login (section 7.5.20 on page 571)
password-thresh (section 7.5.24 on page 576)
7.5.22 timeout login response
This command sets the interval that the system waits for a user to log into the
CLI. Use the no form to restore the default setting.
Syntax
timeout login response [seconds]
no timeout login response
seconds - Integer that specifies the timeout interval.
(Range: 0 - 300 seconds; 0: disabled)
Default Setting
CLI: Disabled (0 seconds)
Telnet: 300 seconds
Command Mode
Line Configuration
Command Usage
If a login attempt is not detected within the timeout interval, the
connection is terminated for the session.
This command applies to both the local console and Telnet connections.
The timeout for Telnet cannot be disabled.