Configuring the ECN330-switch
150 1553-KDU 137 365 Uen D 2006-06-16
Web – Click Security, 802.1X, Port Configuration. Modify the parameters
required, and click Apply.
Figure 52 802.1X Port Configuration
CLI – This example sets the 802.1X parameters on port 2. For a description of
the additional fields displayed in this example, see “show dot1x” on page 4-84.
Console(config)#interface ethernet 1/2
Console(config-if)#dot1x port-control auto
Console(config-if)#dot1x re-authentication
Console(config-if)#dot1x max-req 5
Console(config-if)#dot1x timeout quiet-period 40
Console(config-if)#dot1x timeout re-authperiod 5
Console(config-if)#dot1x timeout tx-period 40
Console(config-if)#end
Console#show dot1x
Global 802.1X Parameters
system-auth-control: enable
802.1X Port Summary
Port Name Status Operation Mode Mode Authorized
1/1 disabled Single-Host ForceAuthorized yes
1/2 enabled Single-Host Auto yes
.
.
.
1/27 disabled Single-Host ForceAuthorized n/a
1/28 disabled Single-Host ForceAuthorized n/a