Configuring the ECN330-switch
96 1553-KDU 137 365 Uen D 2006-06-16
CLI – Enter Line Configuration mode for a virtual terminal, then specify the
connection parameters as required. To display the current virtual terminal
settings, use the show line command from the Normal Exec level.
6.3.13 Configuring Event Logging
The ECN330-switch allows the logging of error messages to be controlled,
including the type of events that are recorded in switch memory, logging to a
remote System Log (syslog) server, and displays a list of recent event
messages.
6.3.13.1 System Log Configuration
The system allows event logging to be enabled or disabled, and which levels are
logged to RAM or flash memory to be specified.
Severe error messages that are logged to flash memory are permanently stored
in the ECN330-switch to assist in troubleshooting network problems. Up to 4096
log entries can be stored in the flash memory, with the oldest entries being
overwritten first when the available log memory (256 kilobytes) has been
exceeded.
The System Logs page allows system messages that are logged to flash or RAM
memory to be configured and limited. The default is for event levels 0 to 3 to be
logged to flash and levels 0 to 7 to be logged to RAM.
Console(config)#line vty
Console(config-line)#login local
Console(config-line)#password 0 secret
Console(config-line)#timeout login response 300
Console(config-line)#exec-timeout 600
Console(config-line)#password-thresh 3
Console(config-line)#end
Console#show line vty
VTY configuration:
Password Threshold: 3 times
Interactive Timeout: 600 sec
Login Timeout: 300 sec
Console#