Configuring the ECN330-switch
971553-KDU 137 365 Uen D 2006-06-16
Command Attributes
System Log Status – Enables/disables the logging of debug or error
messages to the logging process. (Default: Enabled)
Flash Level – Limits log messages saved to the ECN330-switch’s
permanent flash memory for all levels up to the specified level. For
example, if level 3 is specified, all messages from level 0 to level 3 will
be logged to flash. (Range: 0-7, Default: 3)
Table 9 Logging Levels
RAM Level – Limits log messages saved to the ECN330-switch’s
temporary RAM memory for all levels up to the specified level. For
example, if level 7 is specified, all messages from level 0 to level 7 will
be logged to RAM. (Range: 0-7, Default: 7)
Note: The Flash Level must be equal to or less than the RAM Level.
Level Severity Name Description
7 Debug Debugging messages
6 Informational Informational messages only
5 Notice Normal but significant condition, such as
cold start
4 Warning Warning conditions (for example, return
false, unexpected return)
3 Error Error conditions (for example, invalid input,
default used)
2 Critical Critical conditions (for example, memory
allocation, or free memory error - resource
exhausted)
1 Alert Immediate action needed
0 Emergency System unusable
* There are only Level 2, 5 and 6 error messages for the current firmware
release.