Configuring the ECN330-switch
98 1553-KDU 137 365 Uen D 2006-06-16
Web – Click System, Log, System Logs. Specify System Log Status, set
the
level of event messages to be logged, and click Apply.
Figure 26 System Logs
CLI – Enable system logging and then specify the level of messages to be
logged to RAM and flash memory. Use the show logging command to display
the current settings.
6.3.13.2 Remote Log Configuration
The Remote Logs page allows the logging of messages that are sent to syslog
servers or other management stations to be configured. Event messages can
also be limited to send only those messages at or above a specified level.
Command Attributes
Remote Log Status – Enables/disables the logging of debug or error
messages to the remote logging process. (Default: Disabled)
Logging Facility – Sets the facility type for remote logging of syslog
messages. There are eight facility types specified by values of 16 to 23.
The facility type is used by the syslog server to dispatch log messages
to an appropriate service.
Console(config)#logging on
Console(config)#logging history ram 0
Console(config)#
Console#show logging flash
Syslog logging: Enabled
History logging in FLASH: level errors
Console#