Upgrading Firmware
1170 1553-KDU 137 365 Uen D 2006-06-16
Figure 241 File Download Procedure
13. To set the new downloaded file as the startup file, use the [S]et Startup
File menu option.
14. When downloading code files has finished, use the [C]hange Baudrate
menu option to change the baud rate of the ECN330’s serial connection
back to 9600 baud.
15. Set the PC’s terminal emulation software baud rate back to 9600 baud.
Press <Enter> to reset communications with the ECN330-switch.
16. Press <Q> to quit the firmware-download mode and boot the ECN330-
switch.
Select>x
Xmodem Receiving Start ::
XMODEM, Successful.
Blocks Received = 3159
Bytes Received = 410440
Errors:
Checksum = 0
Complement = 0
Duplicates = 0
Image downloaded to buffer.
[R]untime
[D]iagnostic
[L]oader (Warning: you sure what you are doing?)
Update Image File:d
Runtime Image Filename : diag_v0002
Updating file system.
File system updated.
[Press any key to continue]