Configuring the ECN330-switch
1051553-KDU 137 365 Uen D 2006-06-16
Web – Select SNTP, Configuration. Modify any of the required parameters, and
click Apply.
Figure 31 SNTP Configuration
CLI – This example configures the ECN330-switch to operate as an SNTP client
and then displays the current time and settings.
6.3.15.2 Setting the Time Zone
SNTP uses Coordinated Universal Time (or UTC, formerly Greenwich Mean
Time, or GMT) based on the time at the Earth’s prime meridian, zero degrees
longitude. To display a time corresponding to the local time, indicate the number
of hours and minutes the time zone is east (before) or west (after) of UTC.
Command Attributes
Current TimeDisplays the current time.
Name – Assigns a name to the time zone. (Range: 1-29 characters)
Hours (0-13) The number of hours before/after UTC.
Console(config)#sntp client
Console(config)#sntp poll 16
Console(config)#sntp server 10.1.0.19 137.82.140.80 128.250.36.2
Console(config)#exit
Console#show sntp
Current Time: Jan 6 14:56:05 2004
Poll Interval: 60
Current Mode: unicast
SNTP Status: Enabled
SNTP Server: 10.1.0.19 137.82.140.80 128.250.36.2
Current Server: 128.250.36.2
Console#