Command Line Interface
11491553-KDU 137 365 Uen D 2006-06-16
Related Commands
show ip pim (section 7.27.44 on page 1161)
7.27.35 ip pim register- suppression
This command configures the register suppression timer on a DR or the keep
alive time on an RP. Use the no form to restore the default setting.
Syntax
ip pim register-suppression <suppression-time>
no ip pim register-suppression
suppression-time - The period during which a DR stops sending
register-encapsulated data to the RP after receiving a RegisterStop
message. It is also used to calculate the KeepaliveTimer by the RP.
(Range: 1-65535 seconds)
Default Setting
60 seconds
Command Mode
Global Configuration
Command Usage
When the DR receives a register-stop message from the RP, it uses the
register suppression time to set the register-stop timer. It then stops
sending register messages and starts the register-stop timer for the
specified group. Afterwards, the DR periodically sends a null-register
message to the RP to determine whether or not the RP wants to start
receiving normal register messages for this group.
When the RP receives a register message for a source for any group, it
uses the register suppression time to set the keep-alive timer for that
group source.