Configuring the ECN330-switch
1131553-KDU 137 365 Uen D 2006-06-16
hosts, they must be enabled in conjunction with the corresponding entries in the
Notification View (page 3-48).
Web – Click SNMP, Configuration. Enter the IP address and community string
for each management station that will receive trap messages, specify the UDP
port, SNMP trap version, trap security level (for v3 clients), trap inform settings
(for v2c/v3 clients), and then click Add. Select the trap types required using the
check boxes for Authentication and Link-up/down traps, and then click Apply.
Figure 35 Configuring SNMP Trap Managers
CLI – This example adds a trap manager and enables authentication traps.
6.4.4 Configuring SNMPv3 Management Access
To configure SNMPv3 management access to the ECN330-switch, follow these
steps:
1. Configure an SNMP engine ID.
2. Specify read and write access views for the ECN330-switch MIB tree.
3. Configure SNMP user groups with the required security model (that is,
SNMP v1, v2c or v3) and security level (that is, authentication and privacy).
Console(config)#snmp-server host 10.1.19.23 batman private
version 2c udp-port 162
Console(config)#snmp-server enable traps authentication
Console(config)#