Command Line Interface
6051553-KDU 137 365 Uen D 2006-06-16
7.5.50 clock timezone
This command sets the time zone for the ECN330’s internal clock.
Syntax
clock timezone <name> hour <hours> minute <minutes>
{before-utc | after-utc}
name - Name of timezone, usually an acronym. (Range: 1-29
characters)
hours - Number of hours before or after UTC. (Range: 1-12 hours
for before-utc and 1-13 hours for after-utc)
minutes - Number of minutes before or after UTC. (Range: 0-59
minutes)
before-utc - Sets the local time zone before (east) of UTC.
after-utc - Sets the local time zone after (west) of UTC.
Default Setting
None
Command Mode
Global Configuration
Command Usage
This command sets the local time zone relative to the Coordinated Universal
Time (UTC, formerly Greenwich Mean Time or GMT), based on the earth’s
prime meridian, zero degrees longitude. To display a time corresponding to
the local time, the number of hours and minutes the time zone is east
(before) or west (after) of UTC must be indicated.
Example
Console(config)#clock timezone Japan hours 8 minute 0 after-UTC
Console(config)#