Command Line Interface
846 1553-KDU 137 365 Uen D 2006-06-16
7.17.1.5 garp timer
This command sets the values for the join, leave and leaveall timers. Use the no
form to restore the timers’ default values.
Syntax
garp timer {join | leave | leaveall} <timer_value>
no garp timer {join | leave | leaveall}
{join | leave | leaveall} - Which timer to set.
timer_value - Value of timer.
Ranges:
join: 20-1000 centiseconds
leave: 60-3000 centiseconds
leavall: 500-18000 centiseconds
Default Setting
join: 20 centiseconds
leave: 60 centiseconds
leaveall: 1000 centiseconds
Command Mode
Interface Configuration (Ethernet, Port Channel)
Command Usage
Group Address Registration Protocol is used by GVRP and GMRP to
register or deregister client attributes for client services within a bridged
LAN. The default values for the GARP timers are independent of the
media access method or data rate. These values should not be changed
unless there are difficulties with GMRP or GVRP registration or
deregistration.
Timer values are applied to GVRP for all the ports on all VLANs.