34
5-4-5. CONV2 IMPROVE
CONV2 IMPROVE 24
MOTION:ADAPTIVE
ANTIALIAS H:NORMAL
ANTIALIAS V:NORMAL
ENHANCE :LEVEL0
Parameter Default
Setting range
(Steps)
Description
MOTION
*1
ADAPTIVE
FIELD
ADAPTIVE
FRM(ODD 1st)
FRM(EVEN 1st)
FIELD: Generates a progressive scan
image from one field of an interlaced
scan image.
The created image has no motion
artifacts, but vertical resolution will be
reduced.
ADAPTIVE:
Detects whether there is motion or no
motion in the scene, and generate an
optimal progressive scan image.
FRM(ODD 1st):
Generates a progressive scan image
from two fields (odd/even) of and
interlaced scan image.
Suitable for the progressive segment
frame input of progressive scan signals.
FRM(EVEN 1st):
Generates a progressive scan image
from two fields (even/odd) of interlaced
scan image.
ANTIALIAS H
*2
NORMAL
WEAK 8-1
NORMAL
STRONG1-8
Performs horizontal anti-aliasing for the
output video image.
WEAK 8 to STRONG 8 (low to high)
This setting cannot be changed if the
conversion is set to the formats indicated
as (DOWN) in the CONV2 Conversion
Table in section 5-4-2.
ANTIALIAS V
*2
NORMAL
WEAK 8-1
NORMAL
STRONG1-8
Performs vertrical anti-aliasing for the
output video image.
WEAK 8 to STRONG 8 (low to high)
This setting cannot be changed if the
conversion is set to the formats indicated
as (DOWN) in the CONV2 Conversion
Table in section 5-4-2.
ENHANCE
*2
LEVEL 0 LEVEL 0-8
Sharpens the output video image.
LEVEL 0 to 8 (low to high)
*1 Common MOTION settings for CONV1 and CONV2. (This setting can be changed from
either the CONV1 IMPROVE or CONV2 IMPROVE menu, and applied to both menus.)
*2 ANTIALIAS and ENHANCE settings cannot be changed if CONV1 U\D MODE is set to
BY-PASS, or the conversion is set to the formats indicated as (BY-PASS) in the CONV2
Conversion Table (see section 5-4-2).
In both cases, the menu as shown below will be displayed.
CONV2 IMPROVE 24
MOTION:FIELD
ANTIALIAS H:NOT ADJ
ANTIALIAS V:NOT ADJ
ENHANCE :NOT ADJUST
IMPORTANT
Setting MOTION to FRM (ODD 1st) or FRM (EVEN 1st) for input signals other than
progressive segment frame inputs causes motion artifacts to appear. In such case,
change the MOTION setting to FIELD or ADAPTIVE.
Menu button