54
5-7-13. CHGOV VID STATUS
This menu is accessible only if the FA-95CO software option is installed.
Settings in this menu will reset themselves whenever CHANGEOVER in the VIDEO INPUT
SET (5-7-1) menu has been set to DISABLE.
CHGOV VID STATUS 64
SDI ERROR :NON-TRG
FORMAT ERR :NON-TRG
CRC ERROR :NON-TRG
BLACK VIDEO:NON-TRG
Parameter Description
SDI ERROR
Displays SDI error trigger status at the time a changeover is performed.
DISABLE: This trigger is disabled.
NON-TRG: This trigger is not activated.
TRIGGER: Changeover is performed due to this trigger.
FORMAT ERR
Displays Format error trigger status at the time a changeover is performed.
DISABLE: This trigger is disabled.
NON-TRG: This trigger is not activated.
TRIGGER: Changeover is performed due to this trigger.
CRC ERROR
Displays CRC error trigger status at the time a changeover is performed.
DISABLE: This trigger is disabled.
NON-TRG: This trigger is not activated.
TRIGGER: Changeover is performed due to this trigger.
BLACK VIDEO
Displays Black Video trigger status at the time a changeover is performed.
DISABLE: This trigger is disabled.
NON-TRG: This trigger is not activated.
TRIGGER: Changeover is performed due to this trigger.
5-7-14. CHGOV AUD STATUS
This menu is accessible only if the FA-95CO software option is installed.
Settings in this menu will reset themselves whenever CHANGEOVER in the VIDEO INPUT
SET (5-7-1) menu has been set to DISABLE.
CHGOV AUD STATUS 65
AUDIO LOSS:NON-TRG
AUDIO ERR :NON-TRG
SILENCE :NON-TRG
Parameter Description
AUDIO LOSS
Displays Audio Loss trigger status at the time a changeover is performed.
DISABLE: This trigger is disabled.
NON-TRG: This trigger is not activated.
TRIGGER: Changeover is performed due to this trigger.
AUDIO ERR
Displays Audio Error trigger status at the time a changeover is performed.
DISABLE: This trigger is disabled.
NON-TRG: This trigger is not activated.
TRIGGER: Changeover is performed due to this trigger.
SILENCE
Displays Audio Silence trigger status at the time a changeover is performed.
DISABLE: This trigger is disabled.
NON-TRG: This trigger is not activated.
TRIGGER: Changeover is performed due to this trigger.