50
5-7-5. SDI ERROR TRG
This menu is accessible only if the FA-95CO software option is installed.
SDI ERROR TRG 56
TRIGGER :DISABLE
DURATION:IMMEDIATE
CHGOV DISABLED
Parameter Default
Setting range
(Steps)
Description
TRIGGER DISABLE
DISABLE
ENABLE
Enables or disables auto
changeover for SDI signal loss, an
unsupported video format, or TRS
error.
DURATION IMMEDIATE
IMMEDIATE
0.5 to 5.0 sec
(0.5 sec)
Sets the duration of SDI signal
loss, unsupported video format or
TRS error detection (in the active
picture area) required to trigger a
changeover.
* The “CHGOV DISABLED” message is displayed if CHANGEOVER is disabled in the
VIDEO INPUT SET (5-7-1) menu or VIDEO TRG is disabled in the CHGOV
(CHANGEOVER) MODE SET (5-7-4) menu. If this message is displayed, a changeover
will not be performed even hough SDI ERROR TRG is enabled.
5-7-6. FORMAT ERROR TRG
This menu is accessible only if the FA-95CO software option is installed.
FORMAT ERR TRG 57
TRIGGER :DISABLE
DURATION:IMMEDIATE
AUTO SYS FORMAT
CHGOV DISABLED
Parameter Default
Setting range
(Steps)
Description
TRIGGER DISABLE
DISABLE
ENABLE
Enables or disables auto
changeover for SDI input and
system format mismatches.
DURATION IMMEDIATE
IMMEDIATE
0.5 to 5.0 sec
(0.5 sec)
Sets the duration of the detected
format mismatch required to trigger
a changeover.
* The “AUTO SYS FORMAT” message is displayed if SYS FRMT is set to AUTO DET in the
5-10-1 FS MODE SET menu. The TRIGGER cannot be enabled when the message is
displayed. To enable the trigger, set SYS FRMT to other than AUTO DET in the FS MODE
SET (5-10-1) menu.
* The “CHGOV DISABLED” message is displayed if CHANGEOVER is disabled in the
VIDEO INPUT SET (5-7-1) menu or VIDEO TRG is disabled in the CHGOV
(CHANGEOVER) MODE SET (5-7-4) menu. If this message is displayed, a changeover
will not be performed even though FORMAT ERROR TRG is enabled.
* FORMAT ERROR TRG also triggers a changeover for SDI input signal loss. If FORMAT
ERROR TRG is enabled and the SDI signal input is lost, a changeover will be performed,
even though SDI ERROR TRG is disabled, based on the FORMAT ERROR TRG
DURATION setting.
Menu button
IN SEL
DOWNMIX
Menu button
IN SEL
DOWNMIX