LED State Module State Module Status Description
Solid
amber
Critical/non-recoverable:
module is halted.
Fatal alarm: module has
failed or shut down.
• CPU CATERR signal asserted.
• MSID mismatch detected (CATERR also asserts for this case).
• CPU 0 is missing.
• CPU thermal trip.
• No power good: power fault.
• Memory module failure when there is only 1 memory module present and hence
no good memory is present.
• Runtime memory uncorrectable error in non-redundant mode.
• DIMM thermal trip or equivalent.
• SSB thermal trip or equivalent.
• Processor ERR2 signal asserted.
• BMC/video memory test failed (module ID LED shows blue/solid-on for this
condition).
• Both U-Boot BMC firmware images are bad (module ID LED shows blue/solid-on
for this condition).
• 240 VA fault.
• Fatal error in processor initialization:
• Processor family not identical
• Processor model not identical
• Processor cache size not identical
• Cannot synchronize processor frequency
• Cannot synchronize Intel® UPI link frequency
• BMC fail authentication with nonrecoverable condition, system hangs at T-1; boot
PCH only, system hangs; PIT failed, system lockdown