Intel® Server D50DNP Family Integration and Service Guide
215
POST Error
Code
Error Message Corrective Action Type
85EF
Memory encountered a Serial Presence Detection(SPD)
failure.CPU1_DIMM_H3
Major
POST Reclaim of non-critical NVRAM variables
BIOS Settings are corrupted
8606
NVRAM variable space was corrupted and has been
reinitialized
Major
8607
Recovery boot has been initiated.
Note: The primary BIOS image may be corrupted, or the
system may hang during POST. A BIOS update is
Fatal
PCI component encountered a SERR error
PCI Express component encountered a PERR error
PCI Express component encountered an SERR error
A6A0
DXE Boot Services driver: Not enough memory available
to shadow a Legacy Option ROM.
Disable option ROM at setup to save
runtime memory.
Minor
F.1 POST Error LED Codes
Before system video initialization, the BIOS and BMC use POST error LED codes to inform users on error
conditions. These POST error LED codes may be displayed alongside other codes on the diagnostic LEDs.
This LED is the replacement of the beeper that was used to emit auditable error codes on the previous
generation platforms. See the following figure for POST error LED location. The BIOS POST error LED code
descriptions are listed in Table 22 and the BMC POST error LED code descriptions are listed in Table 23.
Figure 267. POST Error LED Location