Intel® Server D50DNP Family Integration and Service Guide
210
Table 21. POST Error Messages and Handling
POST Error
Code
Error Message Corrective Action Type
0012
System RTC date/time not set
Set date and time
Major
0048
Password check failed
Put right password.
Major
0140
PCI component encountered a PERR error
Major
0141
PCI resource conflict
Major
0146 PCI out of resources error
Enable Memory Mapped I/O above 4
GB item at SETUP to use 64-bit MMIO.
Major
0147
Some option ROMs are not loaded because the
verification fails when the Secure Boot option is enabled.
Minor
0191
Processor core/thread count mismatch detected
Use identical CPU type.
Fatal
0192
Processor cache size mismatch detected
Use identical CPU type.
Fatal
0194
Processor family mismatch detected
Use identical CPU type.
Fatal
0195
Processor Intel® UPI link frequencies unable to
synchronize
Fatal
0196
Processor model mismatch detected
Use identical CPU type.
Fatal
0197
Processor frequencies unable to synchronize
Use identical CPU type.
Fatal
5220
BIOS Settings reset to default settings
Major
5221
Passwords cleared by jumper
Major
5224 Password clear jumper is Set
Recommend reminding user to install
BIOS password as BIOS admin
password is the main keys for several
BIOS security features.
Major
8130
CPU 0 disabled
Major
8131
CPU 1 disabled
Major
8160
CPU 0 unable to apply microcode update
Major
8161
CPU 1 unable to apply microcode update
Major
8170
CPU 0 failed Self-Test (BIST)
Major
8171
CPU 1 failed Self-Test (BIST)
Major
8180
CPU 0 microcode update not found
Minor
8181
CPU 1 microcode update not found
Minor
8190
Watchdog timer failed on last boot.
Major
8198
OS boot watchdog timer failure.
Major
8300
Baseboard Management Controller failed self-test.
Major
8305
Hot Swap Controller failure
Major
83A0
Management Engine (ME) failed self-test.
Major
83A1
Management Engine (ME) Failed to respond.
Major
84F2
Baseboard management controller failed to respond
Major
84F3
Baseboard Management Controller in Update Mode.
Major
84F4
Baseboard Management Controller Sensor Data Record
empty.
Update right SDR. Major
84FF System Event Log full
Clear SEL through EWS or SELVIEW
utility.
Minor
85FC
Memory component could not be configured in the
selected RAS mode
Major
8501
Memory Population Error
Plug DIMM at right population.
Major
8502
PMem invalid DIMM population found on the system.
Follow valid POR for PMem DIMM.
Major
8520
Memory failed test/initialization CPU0_DIMM_A1
Remove the disabled DIMM.
Major

Table of Contents