Appendix 2 Error Information & Solution
Error Description Solutions
The setting value of jog deceleration exceeded
the range.
Set the parameter setting value to more than 0.
The setting value of jog jerk exceeded the range.
Set the parameter setting value to more than 0.
Motor-side gear ratio setting value exceeded the
range.
Set the parameter setting value to 1 ~ 65535.
Machine-side gear ratio setting value exceeded
the range.
Set the parameter setting value to 1 ~ 65535.
1052 4178 The setting value for the number of pulses per
rotation exceeded the range.
Set the parameter setting value to be greater than 0 and less
than or equal to 4294967295.
1053 4179 Connection device setting value exceeded the
Set the device number of the slave that can be supported. The
node setting range is 0(no connection device), and 1 ~ 64.
1054 4180 Axis type setting value exceeded the range. Set the parameter setting value to '0: actual axis' or '1: virtual
1055 4181 Speed command unit setting value exceeded the
range.
Set the parameter setting value from '0: unit/sec', '1: unit/min', '2:
rpm'.
Servo On cannot be executed due to occurrence
of servo drive errors.
Execute Servo On after checking the error factor of the servo
drive and removing the servo drive error.
Servo On command was executed again in the
middle of processing Servo On.
Check whether the Servo On command was performed again in
the middle of processing Servo On in program or XG5000.
It is not possible to complete Servo On because
the servo drive cannot be changed to
Check the status of the servo drive. The Servo On command
may not be executed in certain circumstances.
1063 4195 It is not possible to complete Servo On because
the servo drive cannot be changed to "Switched
Check the status of the servo drive. The Servo On command
may not be executed in certain circumstances.
It is not possible to complete Servo On because
the servo drive cannot be changed to "Operation
Check the status of the servo drive. The Servo On command
may not be executed in certain circumstances.
It is not possible to complete Servo On because
"Quick Stop" of servo drive is enabled.
Check the status of the servo drive. The Servo On command
may not be executed in certain circumstances.
Servo Off command was executed again in the
middle of processing Servo Off.
Check whether the Servo Off command was performed again in
the middle of processing Servo Off in program or XG5000.
1067 4199 The execution of Servo Off command was not
Check the status of the servo drive.
1070 4208 It exceeded the servo error reset monitoring time. The servo drive error has not been cleared even after the error
reset monitoring time set in the axis parameter went by. Execute
the error reset command again after removing the servo drive
Commands that use absolute coordinates cannot
be executed at absolute coordinates of the state
Execute the absolute coordinate operation command after
making the determined origin state with homing command or
current position setting command.
1081 4225 In infinite length repeat enable state, the target
position was beyond the range of infinite length
repeat position from the direction specification.
Set the target position within the infinite length repeat position
from the direction specification.