4
4.11 Fine Tuning during Test Runs (Adjust the Control Function)
SIEPCYEUOQ2V01A Q2V Technical Manual 133
Table 4.18 Parameters for Fine Tuning the Drive (A1-02 = 2 [OLVector])
Issue Parameter
Number
Possible Solutions Default Recommended
Setting
Unsatisfactory motor torque and speed
response
Hunting or oscillation at mid-range
speeds (10 Hz to 40 Hz)
n2-01 [AFR Gain]
To increase the speed of torque or speed response, decrease
the setting value in increments of 0.05.
If hunting or oscillation occur, decrease the setting value in
increments of 0.05.
1.00 0.50 - 2.00
n2-02 [AFR Time 1]
To increase the speed of torque or speed response, decrease
the setting value in increments of 10 ms and examine the
response.
If hunting or oscillation occur or if the load inertia is too
much, increase the setting value in increments of 50 ms and
examine the response.
Note:
Make sure that this parameter setting is: n2-02 n2-03 [AFR
Time 2] holds true.
When you adjust n2-02, you must also increase the C4-02
[Trq Comp Delay Time] value by the same ratio.
50 ms 50 ms to 2000 ms
ov [overvoltage] occurs when the drive
stops accelerating, starts to decelerate, or
when there are large changes in the load.
n2-03 [AFR Time 2]
If ov occurs, increase the setting value in increments of 50 ms
and examine the response.
If the response is not sufficient, decrease the setting value in
increments of 10 ms and examine the response.
Note:
Make sure that this parameter setting is: n2-02 [AFR Time 1]
n2-03. When you adjust n2-03, you must also increase the
C4-06 [M2 Trq Comp Delay Time] value by the same ratio.
750 ms 750 ms to 2000 ms
C4-06 [M2 Trq
Comp Delay Time]
If ov occurs, increase the setting value in increments of 10 ms
and examine the response.
If the response is not sufficient, decrease the setting value in
increments of 2 ms and examine the response.
Note:
Make sure that this parameter setting is: C4-02 [Trq Comp
Delay Time] C4-06.
When you adjust C4-06, you must also increase the n2-03
[AFR Time 2] value by the same ratio.
150 ms 150 ms to 750 ms
Unsatisfactory motor torque and speed
response
Hunting or oscillation
C4-02 [Trq Comp
Delay Time]
If torque or speed response are slow, decrease the setting
value in increments of 2 ms.
If hunting or oscillation occur, increase the setting value in
increments of 10 ms.
Note:
Make sure that this parameter setting is: C4-02 C4-06 [M2
Trq Comp Delay Time].
When you adjust C4-02, you must also increase the n2-02
[AFR Time 1] value by the same ratio.
20 ms
*1
20 ms - 100 ms
*1
Speed response is slow.
Speed is not stable.
C3-02 [Slip Comp
Delay Time]
If speed response is slow, decrease the setting value in
increments of 10 ms.
If speed is not stable, increase the value in increments of 10
ms.
200 ms 
*1
100 ms to 500 ms
Speed precision is unsatisfactory.
C3-01 [Slip Comp
Gain]
If speed is too slow, increase the setting value in increments of
0.1.
If speed is too fast, decrease the setting value in increments of
0.1.
1.0
*2
0.5 - 1.5
The volume of the motor excitation
sound is too high.
Hunting or oscillation at low speeds (10
Hz or lower)
C6-02 [Carrier
Frequency
Selection]
If the volume of the motor excitation sound is too high,
increase the carrier frequency.
If hunting or oscillation occur at low speeds, decrease the
carrier frequency.
7(Swing PWM1)
*3
0 to upper limit
value
Torque at low speeds (10 Hz or lower)
is not sufficient. speed response is slow.
Speed response is slow.
Large initial vibration at start up.
E1-08 [Mid A
Voltage]
E1-10 [Min
Output Voltage]
If torque or speed response are slow, increase the setting
value.
If there is large initial vibration at start up, decrease the setting
value
Note:
If you set the value too high, the drive can output a large
torque reference although the load is light.
E1-08: 12.0 V
*2
E1-10: 2.5 V
*2
Default setting +/- 2
V
*4
*1 The default setting changes when the settings for A1-02 [Control Method] and o2-04 [Drive KVA Selection] change.
*2 The default setting changes when the settings for A1-02 [Control Method] and E1-03 [V/f Pattern Selection] change.
*3 The default setting changes when the settings for C6-01 [Normal / Heavy Duty Selection] and o2-04 change.
*4 Recommended settings are for 200 V class drives. Multiply the voltage by 2 for 400 V class drives.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron Q2V Series and is the answer not in the manual?

Omron Q2V Series Specifications

General IconGeneral
BrandOmron
ModelQ2V Series
CategoryInverter
LanguageEnglish

Related product manuals