12.6 F: OPTIONS
558 SIEPCYEUOQ2V01A Q2V Technical Manual
4 : RUN Reverse
■ F6-55: DNet Baud Monitor
No.
(Hex.)
Name Description
Default
(Range)
F6-55
(03C6)
DNet Baud Monitor
Sets the function to see the actual DeviceNet communications speed using the keypad. This
parameter functions as a monitor only.
0
(0 - 2)
0 : 125 kbps
1 : 250 kbps
2 : 500 kbps
■ F6-56: DNet Speed Scale Factor
No.
(Hex.)
Name Description
Default
(Range)
F6-56
(03D7)
DNet Speed Scale Factor
Sets the speed scale for DeviceNet communication.
0
(-15 - +15)
■ F6-57: DNet Current Scale Factor
No.
(Hex.)
Name Description
Default
(Range)
F6-57
(03D8)
DNet Current Scale Factor
Sets the current scale of the DeviceNet communication master.
0
(-15 - +15)
■ F6-58: DNet Torque Scale Factor
No.
(Hex.)
Name Description
Default
(Range)
F6-58
(03D9)
DNet Torque Scale Factor
Sets the torque scale of the DeviceNet communication master.
0
(-15 - +15)
■ F6-59: DNet Power Scaling
No.
(Hex.)
Name Description
Default
(Range)
F6-59
(03DA)
DNet Power Scaling
Sets the power scale of the DeviceNet communication master.
0
(-15 - +15)
■ F6-60: DNet Voltage Scale
No.
(Hex.)
Name Description
Default
(Range)
F6-60
(03DB)
DNet Voltage Scale
Sets the voltage scale of the DeviceNet communication master.
0
(-15 - +15)
■ F6-61: DNet Time Scale
No.
(Hex.)
Name Description
Default
(Range)
F6-61
(03DC)
DNet Time Scale
Sets the time scale of the DeviceNet communication master.
0
(-15 - +15)
■ F6-62: DNet Heartbeat Interval
No.
(Hex.)
Name Description
Default
(Range)
F6-62
(03DD)
DNet Heartbeat Interval
Sets the heartbeat for DeviceNet communication. Set this parameter to 0 to disable the heartbeat
function.
0
(0 - 10)