EasyManuals Logo

Omron Q2V Series User Manual

Omron Q2V Series
734 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #557 background imageLoading...
Page #557 background image
Parameter Details
12
12.6 F: OPTIONS
SIEPCYEUOQ2V01A Q2V Technical Manual 557
6 : 500 kbps
7 : 800 kbps
8 : 1 Mbps
F6-50: DNet MAC Address
No.
(Hex.)
Name Description
Default
(Range)
F6-50
(03C1)
DNet MAC Address
Sets the MAC address for DeviceNet communication. Restart the drive after you change the
parameter setting.
0
(0 - 64)
Note:
Be sure to set a MAC address that is different than all other node addresses. Do not set this parameter to 0. Incorrect parameter settings
will cause AEr [Station Address Setting Error] errors and the MS LED on the option will flash.
F6-51: DNet Baud Rate
No.
(Hex.)
Name Description
Default
(Range)
F6-51
(03C2)
DNet Baud Rate
Sets the DeviceNet communications speed. Restart the drive after you change the parameter
setting.
0
(0 - 4)
0 : 125 kbps
1 : 250 kbps
2 : 500 kbps
3 : Adjustable from Network
The controller sets the communications speed.
4 : Detect Automatically
The drive detects the network communication speed and automatically adjusts the communications speed.
F6-52: DNet PCA Setting
No.
(Hex.)
Name Description
Default
(Range)
F6-52
(03C3)
DNet PCA Setting
Sets the format of data that the DeviceNet communication master sends to the drive.
21
(0 - 255)
Note:
If F6-52 and F6-53 [DNet PPA Setting] are not correct, the value is reset to default.
F6-53: DNet PPA Setting
No.
(Hex.)
Name Description
Default
(Range)
F6-53
(03C4)
DNet PPA Setting
Sets the format of data that the drive sends to the DeviceNet communication master.
71
(0 - 255)
Note:
If F6-52 [DNet PCA Setting] and F6-53 are not correct, the value is reset to default.
F6-54: DNet Idle Fault Detection
No.
(Hex.)
Name Description
Default
(Range)
F6-54
(03C5)
DNet Idle Fault Detection
Sets the function to detect EF0 [Option Card External Fault] when the drive does not receive
data from the DeviceNet master.
0
(0 - 4)
0 : Enabled
1 : Disabled, No Fault Detection
Does not detect EF0 issues.
2 : Vendor Specific
3 : RUN Forward

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron Q2V Series and is the answer not in the manual?

Omron Q2V Series Specifications

General IconGeneral
BrandOmron
ModelQ2V Series
CategoryInverter
LanguageEnglish

Related product manuals