12.7 H: TERMINALS
628 SIEPCYEUOQ2V01A Q2V Technical Manual
WARNING! Sudden Movement Hazard. Before you do a test run, make sure that the setting values for virtual input and output
function parameters are correct. Virtual input and output functions can have different default settings and operation than wired
input and output functions. Incorrect function settings can cause serious injury or death.
Figure 12.104 Virtual Analog I/O Functional Block Diagram
Figure 12.105 Virtual Digital I/O Functional Block Diagram
Note:
Refer to H1: DIGITAL INPUTS on page 566 for more information on the virtual digital input setting values.
Refer to H2: DIGITAL OUTPUTS on page 587 for more information on the virtual digital output setting values.
Refer to H3: ANALOG INPUTS on page 608 for more information on the virtual analog input setting values.
Refer to H4: ANALOG OUTPUTS on page 618 for more information on the virtual analog output setting values.
You cannot set 5 [3-Wire Seq.] and 20 to 2F [External Fault] to H7-01 to H7-04 [Virtual In1 Select Function to Virtual In4 Select
Function].
If the terminal is not used, set H7-01 to H7-04 = 0. However, the through mode function is not supported.
H7-00: Virtual MFIO Selection
No.
(Hex.)
Name Description
Default
(Range)
H7-00
(116F)
Expert
Virtual MFIO Selection
Sets the function to enable and disable the virtual I/O function. Set this parameter to 1 to operate
the virtual I/O function.
0
(0, 1)
0 : Disabled
1 : Enabled
H7-01: Virtual In1 Select Function
No.
(Hex.)
Name Description
Default
(Range)
H7-01
(1185)
Expert
Virtual In1 Select Function
Sets the function that enters the virtual input set in H7-10 [Virtual Out1 Select Function].
0
(0 - 4, 6 - 19F)
H7-02: Virtual In2 Select Function
No.
(Hex.)
Name Description
Default
(Range)
H7-02
(1186)
Expert
Virtual In2 Select Function
Sets the function that enters the virtual input set in H7-12 [Virtual Out2 Select Function].
0
(0 - 4, 6 - 19F)
H7-03: Virtual In3 Select Function
No.
(Hex.)
Name Description
Default
(Range)
H7-03
(1187)
Expert
Virtual In3 Select Function
Sets the function that enters the virtual input set in H7-14 [Virtual Out3 Select Function].
0
(0 - 4, 6 - 19F)
H7-01
[Virtual Multi-Function
Input 1]
H7-11
[Virtual Output
1 Delay Time]
H7-10
[Virtual Multi-Function