Parameter Details
12
12.7 H: TERMINALS
SIEPCYEUOQ2V01A Q2V Technical Manual 629
H7-04: Virtual In4 Select Function
No.
(Hex.)
Name Description
Default
(Range)
H7-04
(1188)
Expert
Virtual In4 Select Function
Sets the function that enters the virtual input set in H7-16 [Virtual Out4 Select Function].
0
(0 - 4, 6 - 19F)
H7-10: Virtual Out1 Select Function
No.
(Hex.)
Name Description
Default
(Range)
H7-10
(11A4)
Expert
Virtual Out1 Select
Function
Sets the function for virtual digital output 1.
0
(0 - 1A7)
H7-11: Virtual Out1 Delay Time
No.
(Hex.)
Name Description
Default
(Range)
H7-11
(11A5)
Expert
Virtual Out1 Delay Time
Sets the minimum ON time for virtual digital output 1.
0.1 s
(0.0 - 25.0 s)
H7-12: Virtual Out2 Select Function
No.
(Hex.)
Name Description
Default
(Range)
H7-12
(11A6)
Expert
Virtual Out2 Select
Function
Sets the function for virtual digital output 2.
0
(0 - 1A7)
H7-13: Virtual Out2 Delay Time
No.
(Hex.)
Name Description
Default
(Range)
H7-13
(11A7)
Expert
Virtual Out2 Delay Time
Sets the minimum ON time for virtual digital output 2.
0.1 s
(0.0 - 25.0 s)
H7-14: Virtual Out3 Select Function
No.
(Hex.)
Name Description
Default
(Range)
H7-14
(11A8)
Expert
Virtual Out3 Select
Function
Sets the function for virtual digital output 3.
0
(0 - 1A7)
H7-15: Virtual Out3 Delay Time
No.
(Hex.)
Name Description
Default
(Range)
H7-15
(11A9)
Expert
Virtual Out3 Delay Time
Sets the minimum ON time for virtual digital output 3.
0.1 s
(0.0 - 25.0 s)
H7-16: Virtual Out4 Select Function
No.
(Hex.)
Name Description
Default
(Range)
H7-16
(11AA)
Expert
Virtual Out4 Select
Function
Sets the function for virtual digital output 4.
0
(0 - 1A7)

Table of Contents