8 Applied Settings
8 - 60
High-function General-purpose Inverter RX2 Series User’s Manual
(Ex.5) When [bb-22] ≠00 and [bb-28] = 03, it restarts using the motor speed feedback.
For motor speed feedback, the feedback input to the input terminals A and B, or feedback input to the
optional cassette PG option unit is required.
(Ex.6) When [bb-22] ≠00 and [bb-28] = 04, it restarts by picking up the frequency, and then after decel-
eration according to the setting, the motor trips when stopped.
Output Current
Overcurrent Detection Level
Free Running
Motor Speed
Inverter
Output
Retry Standby Time
Output signal
[AL]
Output Current
Overcurrent Detection Level
Free Running
Motor Speed
Inverter
Output
Overcurrent Error
Retry Standby Time
Overvoltage Error
Output signal
[AL]