EasyManua.ls Logo

Omron RX2 Series - Page 623

Omron RX2 Series
920 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 - 31
9 Communications Functions
High-function General-purpose Inverter RX2 Series User’s Manual
9-5 Modbus Communication Register Number List
9
9-5-2 Group d Register List
0439h 0438h Trip monitor 5 Factor
dE-15 R
1 to 255 1
043Ah 0439h
Trip monitor 5 Output fre-
quency
-59000 to 59000 0.01(Hz)
043Bh 043Ah (with sign)
043Ch 043Bh
Trip monitor 5 Output cur-
rent
0 to 65535 0.01(A)
043Dh 043Ch
Trip monitor 5 P-N DC volt-
age
0 to 10000 0.1(Vdc)
043Eh 043Dh Trip monitor 5 Inverter state
0 to 8
*5
1
043Fh 043Eh Trip monitor 5 LAD state
0 to 5
*5
1
0440h 043Fh
Trip monitor 5 INV control
mode
0 to 11
*5
1
0441h 0440h Trip monitor 5 Limit state
0 to 6
*5
1
0442h 0441h Trip monitor 5 Special state
0 to 6
*5
1
0444h 0443h Trip monitor 5 RUN time
0 to 1000000 1(hr)
0445h 0444h
0446h 0445h
Trip monitor 5 Power ON
time
0 to 1000000 1(hr)
0447h 0446h
0448h
Trip monitor 5 Absolute time
(year, month)
00 to 99 (BCD code)
01 to 12 (BCD code)
-
0449h 0448h
Trip monitor 5 Absolute time
(day, day of the week)
01 to 31 (BCD code)
00 to 06 (BCD code)
-
044Ah 0449h
Trip monitor 5 Absolute time
(hour, minute)
00 to 23 (BCD code)
00 to 59 (BCD code)
-
044Dh 044Ch Trip monitor 6 Factor
dE-16 R
1 to 255 1
044Eh 044Dh
Trip monitor 6 Output fre-
quency
-59000 to 59000 0.01(Hz)
044Fh 044Eh (with sign)
0450h 044Fh
Trip monitor 6 Output cur-
rent
0 to 65535 0.01(A)
0451h 0450h
Trip monitor 6 P-N DC volt-
age
0 to 10000 0.1(Vdc)
0452h 0451h Trip monitor 6 Inverter state
0 to 8
*5
1
0453h 0452h Trip monitor 6 LAD state
0 to 5
*5
1
0454h 0453h
Trip monitor 6 INV control
mode
0 to 11
*5
1
0455h 0454h Trip monitor 6 Limit state
0 to 6
*5
1
0456h 0455h Trip monitor 6 Special state
0 to 6
*5
1
0458h 0457h Trip monitor 6 RUN time
0 to 1000000 1(hr)
0459h 0458h
045Ah 0459h
Trip monitor 6 Power ON
time
0 to 1000000 1(hr)
045Bh 045Ah
045Ch 045Bh
Trip monitor 6 Absolute time
(year, month)
00 to 99 (BCD code)
01 to 12 (BCD code)
-
045Dh 045Ch
Trip monitor 6 Absolute time
(day, day of the week)
01 to 31 (BCD code)
00 to 06 (BCD code)
-
045Eh 045Dh
Trip monitor 6 Absolute time
(hour, minute)
00 to 23 (BCD code)
00 to 59 (BCD code)
-
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W Monitor or setting data
Resolution

Table of Contents

Related product manuals