9 Communications Functions
9 - 34
High-function General-purpose Inverter RX2 Series User’s Manual
04B1h 04B1h Retry monitor 1 Factor
dE-31 R
1 to 255 1
04B2h 04B1h
Retry monitor 1 Output fre-
quency
-59000 to 59000 0.01(Hz)
04B3h 04B2h (with sign)
04B4h 04B3h
Retry monitor 1 Output cur-
rent
0 to 65535 0.01(A)
04B5h 04B4h
Retry monitor 1 P-N DC volt-
age
0 to 10000 0.1(Vdc)
04B6h 04B5h
Retry monitor 1 Inverter
state
0 to 8
*5
1
04B7h 04B6h Retry monitor 1 LAD state
0 to 5
*5
1
04B8h 04B7h
Retry monitor 1 INV control
mode
0 to 11
*5
1
04B9h 04B8h Retry monitor 1 Limit state
0 to 6
*5
1
04BAh 04B9h Retry monitor 1 Special state
0 to 6
*5
1
04BCh 04BBh Retry monitor 1 RUN time
0 to 1000000 1(hr)
04BDh 04BCh
04BEh 04BDh
Retry monitor 1 Power ON
time
0 to 1000000 1(hr)
04BFh 04BEh
04C0h 04BFh
Retry monitor 1 Absolute
time (year, month)
00 to 99 (BCD code)
01 to 12 (BCD code)
-
04C1h 04C0h
Retry monitor 1 Absolute
time (day, day of the week)
01 to 31 (BCD code)
00 to 06 (BCD code)
-
04C2h 04C1h
Retry monitor 1 Absolute
time (hour, minute)
00 to 23 (BCD code)
00 to 59 (BCD code)
-
04C5h 04C4h Retry monitor 2 Factor
dE-32 R
1 to 255 1
04C6h 04C5h
Retry monitor 2 Output fre-
quency
-59000 to 59000 0.01(Hz)
04C7h 04C6h (with sign)
04C8h 04C7h
Retry monitor 2 Output cur-
rent
0 to 65535 0.01(A)
04C9h 04C8h
Retry monitor 2 P-N DC volt-
age
0 to 10000 0.1(Vdc)
04CAh 04C9h
Retry monitor 2 Inverter
state
0 to 8
*5
1
04CBh 04CAh Retry monitor 2 LAD state
0 to 5
*5
1
04CCh 04CBh
Retry monitor 2 INV control
mode
0 to 11
*5
1
04CDh 04CCh Retry monitor 2 Limit state
0 to 6
*5
1
04CEh 04CDh Retry monitor 2 Special state
0 to 6
*5
1
04D0h 04CFh Retry monitor 2 RUN time
0 to 1000000 1(hr)
04D1h 04D0h
04D2h 04D1h
Retry monitor 2 Power ON
time
0 to 1000000 1(hr)
04D3h 04D2h
04D4h 04D3h
Retry monitor 2 Absolute
time (year, month)
00 to 99 (BCD code)
01 to 12 (BCD code)
-
04D5h 04D4h
Retry monitor 2 Absolute
time (day, day of the week)
01 to 31 (BCD code)
00 to 06 (BCD code)
-
04D6h 04D5h
Retry monitor 2 Absolute
time (hour, minute)
00 to 23 (BCD code)
00 to 59 (BCD code)
-
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W Monitor or setting data
Resolution