9 - 47
9 Communications Functions
High-function General-purpose Inverter RX2 Series User’s Manual
9-5 Modbus Communication Register Number List
9
9-5-4 Group A Register List
2FF2h 2FF1h
Acceleration time setting for
Multispeed-12
AC-74
(HIGH)
R/W
0 to 360000 0.01(s)
2FF3h 2FF2h
AC-75
(LOW)
R/W
2FF4h 2FF3h
Deceleration time setting for
Multispeed-12
AC-76
(HIGH)
R/W
0 to 360000 0.01(s)
2FF5h 2FF4h
AC-77
(LOW)
R/W
2FF6h 2FF5h
Acceleration time setting for
Multispeed-13
AC-78
(HIGH)
R/W
0 to 360000 0.01(s)
2FF7h 2FF6h
AC-79
(LOW)
R/W
2FF8h 2FF7h
Deceleration time setting for
Multispeed-13
AC-80
(HIGH)
R/W
0 to 360000 0.01(s)
2FF9h 2FF8h
AC-81
(LOW)
R/W
2FFAh 2FF9h
Acceleration time setting for
Multispeed-14
AC-82
(HIGH)
R/W
0 to 360000 0.01(s)
2FFBh 2FFAh
AC-83
(LOW)
R/W
2FFCh 2FFBh
Deceleration time setting for
Multispeed-14
AC-84
(HIGH)
R/W
0 to 360000 0.01(s)
2FFDh 2FFCh
AC-85
(LOW)
R/W
2FFEh 2FFDh
Acceleration time setting for
Multispeed-15
AC-86
(HIGH)
R/W
0 to 360000 0.01(s)
2FFFh 2FFEh
AC-87
(LOW)
R/W
3000h 2FFFh
Deceleration time setting for
Multispeed-15
AC-88
(HIGH)
R/W
0 to 360000 0.01(s)
3001h 3000h
AC-89
(LOW)
R/W
300Dh 300Ch
Torque reference input source
selection
Ad-01 R/W
01: Ai1 terminal input
02: Ai2 terminal input
03: Ai3 terminal input
04: (Reserved)
05: (Reserved)
06: (Reserved)
07: Parameter setting
08: RS 485
09: Option 1
10: Option 2
11: Option 3
12: Pulse string input: Inverter
13: Pulse string input: Option
15: PID calculation
-
300Eh 300Dh
Torque reference value set-
ting
Ad-02 R/W
-500.0 to 500.0 (%)
(Limited at a torque equivalent to
200% of inverter ND rating)
0.1(%)
30
0Fh
300Eh
Polarity selection for torque
reference
Ad-03 R/W
00: As per the sign
01: Follow the revolution direction
-
3010h 300Fh
Switching time of Speed con-
trol to Torque control
Ad-04 R/W 0 to 1000 1(ms)
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W Monitor or setting data
Resolution